MIL-DTL-18714F (OS)
TABLE I. First article and quality conformance inspection plan
Test or Examination
Requirement
Test
First Article Inspection
Quality Conformance Inspection
Paragraph
Paragraph
Sample Size
Accept
Reject
Sample Size
Accept
Reject
1301/
1051/
Radiographic
3.3
4.6.1
0
1
0
1
1301/
1051/
Electrical resistance
3.6
4.6.4
0
1
0
1
Functional3/
25
3.7
4.6.5
30
1
0
1
0
Functioning time
a.
1
0
1
0
b.
Misfire
1
0
1
0
Blowback
c.
1
0
1
0
Split stock, split
d.
tube, or parts
detached
Vibration3/
3.8
4.6.6
9
0
Non-functional
a.
0
1
N/A
N/A
Integrity of stock,
b., c.
0
1
N/A
N/A
tube, assembly, etc.
d.
0
1
N/A
N/A
e.
0
1
N/A
N/A
Ballistic ejection time3/
3.9
4.6.7
20
0
1
Detail Strip3/
3.5
4.6.3
56
56
Critical characteristics
0
1
0
1
Major characteristics
0
1
0
1
52/
52/
Black powder
3.4
4.6.2
0
1
0
1
moisture content
Parts and
3.1
4.3.1 and
5 each
0 per item
1 per item
MIL-STD-1916 and Tables II through XXVIII
sub-assemblies
4.4.3
Packaging
Section 6.4.1
4.6.8
1 pk
0
1
1 pk
0
1
1/
Radiographic examination and resistance test shall be performed on all samples prior to any other test or examination.
2/
Samples shall be taken from those for the detail strip examination.
3/
Performed only by the government facility as designated in the contract or order.