MIL-DTL-0050869F (AR)
9287617 - Cup and Skirt Inert Loading Assembly
INSPECTION EQUIPMENT DRAWINGS
8827889 - Gage, Receiver, Profile and Alignment, 40MM Cartridge
8827890 - Gage, Plug, Acceptance Check
8827895 - Limit Check
(Copies of these drawings may be requested online at drawing-request@pica.army.mil, or from
U.S. Army ARDEC, ATTN: AMSRD-AAR-AIS-TD, Picatinny NJ 07806-5000.)
2.3 Non-Government publications. The following documents form a part of this
document to the extent specified herein. Unless otherwise specified, the issue of the documents
are those cited in the solicitation or contract.
AMERICAN SOCIETY FOR TESTING AND MATERIALS INTERNATIONAL
(ASTM)
ASTM B117
Standard Method of Salt Spray (fog) Testing
ASTM E1255
Standard Practice for Radioscopy
(Copies may be requested online at www.astm.org or ordered from the American Society for
Testing and Materials, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959)
2.4 Order of precedence. In the event of a conflict between the text of this document
and the references cited herein, the text of this document takes precedence. Nothing in this
document, however, supersedes applicable laws and regulations unless a specific exemption has
been obtained.
3. REQUIREMENTS
3.1 First article. When specified in the solicitation or contract order (see 6.2), a sample
shall be subjected to first article inspection in accordance with 4.3.
3.2 Materials. Materials, parts and assemblies shall comply with requirements specified
on the applicable drawings and referenced specifications.
3.3 Transportation vibration. Prior to transportation vibration test, the fuze assembly,
shall be x-rayed and shall not be armed or partially armed (as evidenced by the detonator
moving any degree from the safe position) or have any safety feature missing or not in its
proper position (i.e. detent, detent spring, setback pin, setback spring), damaged parts or foreign
material. After performance of the transportation vibration test the fuze assembly shall be x-
rayed again and shall not be armed or partially armed (as evidenced by the detonator moving
any degree from the safe position) or have any safety feature not in its proper position, damaged
parts or foreign material and shall meet the requirements of functioning (3.6) and non-
functioning (3.7).
3
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business