MIL-DTL-18714F (OS)
TABLE XX. Conformance inspection by classification of characteristics for ignition element, electric; MK 1 MOD 1 assembly, drawing
number 2434753 Continued
Conformance
Requirement
Inspection Method
Classification
Examination or Test
Criteria
Paragraph
Reference
Major
AIE
3.2
Level IV
M106
Note 10: Immediately prior to next assembly apply moisture proof varnish,
find no. 7, 360° around in two places as shown for seal.
AIE
3.2
Level IV
.231 +.007/-.004
M107
NSIG
3.2
Level IV
[Ø .009(M)][A(M)] (for Ø .569 +.001/-.003)
M108
AIE
3.2
Level IV
Ø .569 +.001/-.003
M109
AIE
3.2
Level IV
.025 min
M110
AIE
3.2
Level IV
.652 ± .016
M111
AIE
3.2
Level IV
R .020 min
M112
AIE
3.2
Level IV
R .010 min
M113
AIE
3.2 & 3.10
Level IV
Note 5: Component parts shall be clean and dry prior to assembly to avoid
M114
accumulation of moisture within the ignition element.
Minor
AIE
3.2
Level II
Ø .174 -A-
201
AIE
3.2
Level II
Note 2: Ignition element cup, find no. 1, shall be assembled to electrode
202
washer and igniter assembly, find no. 2.