MIL-DTL-18714F (OS)
TABLE XXV. Conformance inspection by classification of characteristics for closing cup, drawing number 2847019
Conformance
Requirement
Inspection Method
Classification
Examination or Test
Criteria
Paragraph
Reference
Critical
None Defined
Major
-M101
.016± .004
Level IV
3.2
AIE
M102
"Constrained state" requirement: when assembled in the primer tube liner
Level IV
3.2
NSIG
and plug assembly, .240 groove, the side walls of the cup shall form a 360°
seal without forming any furrows, gaps or open channels. Navy gage no.
6656381 may be used to verify the constrained state.
Minor
201
R .080 +.030/-.040
Level II
3.2
AIE
202
[.01] (F) (for dim .080 +.030/-.040)
Level II
3.2
AIE
203
.230 ± .020
Level II
3.2
AIE
204
Ø .630 +.020/-.000 AVG
Level II
3.2
AIE
205
.600 +.005/-.015 (T) to R .080
Level II
3.2
AIE
206
[.01] (F) (for dim .600 +.005/-.015 (T) to R .080)
Level II
3.2
AIE
207
.030 +.014/-.014 AVG
Level II
3.2
AIE
208
.016 +.004 (Upper Tol)
Level II
3.2
AIE
209
Note 2: Material: insulation, electrical, paper, MIL-I-695, Type R.
Level II
3.2
COC
210
Note 3: Dimensions apply to closing cup in free state at the time it is
Level II
3.2
AIE
manufactured.
41