MIL-DTL-18714F (OS)
TABLE XXVI. Conformance inspection by classification of characteristics for cup, inner, drawing number 3208399 Continued
Conformance
Requirement
Inspection Method
Classification
Examination or Test
Criteria
Paragraph
Reference
Minor
NSIG
3.2
Level II
209
Note 3: Over time, cup dimensions may shift due to release of internal
stresses and effects of humidity. However, the cup will still satisfy its
functional requirements at the next level of assembly, which is verified by
satisfying the "constrained state" (see note 5).
NSIG
3.2
Level II
210
Note 4: The sidewalls of the cup shall be pliable to allow proper function of
the cup in the next higher assembly, as described in the "constrained state"
requirement.
AIE/NSIG
3.2
Level IV & II
Verification requirements for first article inspection shall be met by the
NOTE
"constrained state". Manufacturer's data showing dimensional
compliance at time of manufacture pertains to the "free state".
44
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business